We have a Kuka KR3 R540 robot that is being integrated into an existing system for vision inspection. The mounting location for the robot is in a tight area between a table and the lexan guarding. With this is being integrated into a portion of a system that was built by a different integrator, would we need to ensure the entire line is meets RIA standards prior to installing this robot or just the station it is being integrated into? Thank you.
See RIA TR R15.506-2014 Technical report "Applicability of ANSI R15.06-2012 for existing Robot Applications. Table 1 Scenarios demonstrating various requirements. Scenario(s) 1. Existing equipment is automated with new robotic equipment, creating a new robot cell: Requirement; Treat the same as a new robot cell and conduct a risk assessment (Clause 4.2.1) Requirements: 7. Robots are added to or removed from an existing robot cell: Requirement; A risk assessment must be completed that address the affected portions. (Clause 4.2.5) Note 2 Meet the requirements of a modified robot cell (4.2.5) and perform a function check to confirm the cell performs as expected. I would do a complete new risk assessment on the entire cell
Ivica Kvasina from KUKA Robotics Corporation | 11/07/2019